Skip to main content

Lifting station Aqualift S Compact

The flexible version for wastewater without sewage.

Reliable and hygienic: the lifting station Aqualift S Compact is a real quick-change artist. It is the first lifting station in our range that can be converted comfortably from a Mono to a Duo system after floor slab installation. Yet that is not the only feature that makes the Aqualift S Compact so special: the free suspension and acoustic decoupling of the pump(s) also makes particularly quiet operation possible.

The Aqualift S Compact is available with a float switch or pneumatic level measurement. The lifting station can also take up and discharge water additionally from the surface through the drain integrated in the black or tileable cover. It is delivered from the factory with either one or two pumps; the new GTF 500 and GTF 500 resistant (for aggressive wastewater such as heating condensate) and the GTF 1200 are the models used here.

Lifting station Aqualift S Compact Duo Tronic
Lifting station Aqualift S Compact Mono, for floor slab installation, tileable
Lifting station Aqualift S Compact Mono Tronic, for floor slab installation, black

Application possibilities

Powerful yet inconspicuous: The Aqualift S Compact simply disappears under a tiled or black cover. It is irrelevant whether it is installed in waterproof concrete or in a floor slab. Once installed, it is still possible to upgrade the Aqualift S Compact at a later date: A Mono system can even easily be converted into a Duo system.


Floor slab installation

The Aqualift S Compact is an almost invisible lifting station if it is installed in the floor slab. The integrated drain in the cover handles basement surface water. Even in the event of a pipe burst or flooding, the Minilift S continually pumps away the wastewater keeping the basement rooms dry.

Installation in waterproof concrete

The KESSEL sealing set for installation in waterproof concrete ensures reliable protection against pressing water. The extension section with a central flange and elastomeric waterproofing membrane enable implementation also in deeper installation situations.

Control

The Aqualift S Compact is available with simple float switch control and also with pneumatic level measurement and a Comfort control unit with the self-diagnosis system SDS that is supplied ready for connection.

Aqualift S Compact lifting station


Pneumatic level measurement

  Load classPumpType of wastewaterType of cover Item no.  
280530S280530S K 3 (EN 1253-1) GTF 500 without sewage Cover plate with slotted cover 280530S
Show
280530SC280530SC K 3 (EN 1253-1) GTF 500 resistant without sewage Cover plate with slotted cover 280530SC
Show
280530X280530X K 3 (EN 1253-1) GTF 500 without sewage tileable cover plate 280530X
Show
280530XC280530XC K 3 (EN 1253-1) GTF 500 resistant without sewage tileable cover plate 280530XC
Show
281230S281230S K 3 (EN 1253-1) GTF 1200 without sewage Cover plate with slotted cover 281230S
Show
281230SC281230SC K 3 (EN 1253-1) GTF 1200 resistant without sewage Cover plate 281230SC
Show
281230X281230X K 3 (EN 1253-1) GTF 1200 without sewage tileable cover plate 281230X
Show
281230XC281230XC K 3 (EN 1253-1) GTF 1200 resistant without sewage tileable cover plate 281230XC
Show

  Load classPumpType of wastewaterType of cover Item no.  
280550S280550S K 3 (EN 1253-1) GTF 500 without sewage Cover plate with slotted cover 280550S
Show
280550SC280550SC K 3 (EN 1253-1) GTF 500 resistant without sewage Cover plate with slotted cover 280550SC
Show
280550X280550X K 3 (EN 1253-1) GTF 500 without sewage tileable cover plate 280550X
Show
280550XC280550XC K 3 (EN 1253-1) GTF 500 resistant without sewage tileable cover plate 280550XC
Show
281250S281250S K 3 (EN 1253-1) GTF 1200 without sewage Cover plate with slotted cover 281250S
Show
281250SC281250SC K 3 (EN 1253-1) GTF 1200 resistant without sewage Cover plate 281250SC
Show
281250X281250X K 3 (EN 1253-1) GTF 1200 without sewage tileable cover plate 281250X
Show
281250XC281250XC K 3 (EN 1253-1) GTF 1200 resistant without sewage tileable cover plate 281250XC
Show

Mechanical level measurement

  Load classPumpType of wastewaterType of cover Item no.  
280500S280500S K 3 (EN 1253-1) GTF 500 without sewage Cover plate with slotted cover 280500S
Show
280500SC280500SC K 3 (EN 1253-1) GTF 500 resistant without sewage Cover plate with slotted cover 280500SC
Show
280500X280500X K 3 (EN 1253-1) GTF 500 without sewage tileable cover plate 280500X
Show
280500XC280500XC K 3 (EN 1253-1) GTF 500 resistant without sewage tileable cover plate 280500XC
Show
281200S281200S K 3 (EN 1253-1) GTF 1200 without sewage Cover plate with slotted cover 281200S
Show
281200SC281200SC K 3 (EN 1253-1) GTF 1200 resistant without sewage Cover plate 281200SC
Show
281200X281200X K 3 (EN 1253-1) GTF 1200 without sewage tileable cover plate 281200X
Show
281200XC281200XC K 3 (EN 1253-1) GTF 1200 resistant without sewage tileable cover plate 281200XC
Show

Shell and Technology Kits

  PumpType of coverInstallation situation Item no.  
280500S-RBK280500S-RBK GTF 500 Cover plate with slotted cover floor slab installation 280500S-RBK
Show
280500X-RBK280500X-RBK GTF 500 tileable cover plate floor slab installation 280500X-RBK
Show
280501S-RBK280501S-RBK GTF 1200 Cover plate with slotted cover floor slab installation 280501S-RBK
Show
280501X-RBK280501X-RBK GTF 1200 tileable cover plate floor slab installation 280501X-RBK
Show
280510S-RBK280510S-RBK GTF 500 Cover plate with slotted cover floor slab installation 280510S-RBK
Show
280510X-RBK280510X-RBK GTF 500 tileable cover plate floor slab installation 280510X-RBK
Show
280511S-RBK280511S-RBK GTF 1200 Cover plate with slotted cover floor slab installation 280511S-RBK
Show
280511X-RBK280511X-RBK GTF 1200 Cover plate with slotted cover floor slab installation 280511X-RBK
Show

  Control unitNumber of pumpsResistant Item no.  
280500-TK280500-TK 1 280500-TK
Show
280500C-TK280500C-TK 1 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 280500C-TK
Show
280530-TK280530-TK Comfort 2 280530-TK
Show
280530C-TK280530C-TK Comfort 2 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 280530C-TK
Show
280550-TK280550-TK Comfort 1 280550-TK
Show
280550C-TK280550C-TK Comfort 1 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 280550C-TK
Show
281200-TK281200-TK 1 281200-TK
Show
281200C-TK281200C-TK 1 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 281200C-TK
Show
281230-TK281230-TK Comfort 2 281230-TK
Show
281230C-TK281230C-TK Comfort 2 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 281230C-TK
Show
281250-TK281250-TK Comfort 1 281250-TK
Show
281250C-TK281250C-TK Comfort 1 Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems 281250C-TK
Show

Not found the right product?

In addition to our standard lifting stations, we develop individual solutions for special requirements – in terms of form, function and dimensioning – at the customer's request. 

Customised solutions